MALDI-TOF-MS Automated sample preparation for uHTS

MALDI-TOF-MS Sample Preparation

Clear advantages for your MALDI-TOF-MS application

  • Parallel sample transfers of 96, 384 and 1536 samples with the CyBio Well vario
  • No interference thanks to intelligent washing routines
  • Homogeneous target spots through automated drying
  • Highly accurate spotting for reliable, automated analyses
  • Software for higher-level process planning of spotting, matrix feeding and washing and drying processes

Several hundred thousand MALDI samples per run

Our automation solutions, specially developed for MALDI-MS applications, accelerate your research. Process several hundred thousand samples fully automatically in a single run. We offer you real walk-away solutions that provide you with highly reproducible, reliable results while saving you valuable time and money.

uHTS integration for MALDI-TOF-MS

Matrix-assisted laser desorption/ionization Time-of-flight mass spectrometry (MALDI-TOF-MS) and ultra-high throughput (uHTS) now go hand in hand. Benefit from the fastest MALDI-TOF-MS system solution on the market: the Bruker Rapiflex MALDI-TOF-MS and automation solutions for sample preparation from Analytik Jena. Whether simple workstation or complex integration – MALDI-TOF-MS applications are diverse and each have special requirements. Analytik Jena offers you fully automated solutions that adapt flexibly to your needs. The spotting of up to 1536 samples on a MALDI plate in less than 10 minutes is possible.

Very small volumes and homogeneous MALDI spots

One sample transfer, 1536 identical spots: The CyBio Well vario pipetter ensures sample integrity and reproducible results through parallel spotting of a complete MALDI target plate.

MALDI sample cleaning – no more interference

The integrated washing routines desalinate the samples and reduce the risk of interference. This leads to significantly better assay conditions and measurement results. With the CyBio Well vario, 1536 samples can be cleaned in parallel in less than 60 seconds.

Active drying for homogeneous MALDI spots

The more homogeneous the individual MALDI spots are, the higher the subsequent analysis quality. Active drying is therefore integrated into our automation solutions for MALDI sample preparation. It ensures controlled crystallization conditions and thus highly uniform spots.

No sample carry-over thanks to intelligent accessories

In order to avoid possible sample carry-over, the cleaning of the pipette tips between the spotting of different assay plates is crucial. You can therefore optionally equip your CyBio Well vario with an automated peak washing station. Both 384 and 1536 well formats can be cleaned in this way. Thanks to highly efficient washing routines, cross-contamination is hardly detectable after just three washing cycles.

Modular and tailor-made solutions

Thanks to the modular design of individual components, you can freely configure the degree of automation. In addition to the Liquid Handling portfolio, Analytik Jena also offers individual automation solutions tailored to your needs.

Software

Software is the key element of automation. Our powerful and scalable software packages enable detailed control of all components of maldi-TOF-MS sample preparation as well as simple process planning. With our software, you can prepare your samples in the same time that the mass spectrometer analyzes them – in less than 10 minutes. You can analyze up to one million samples in less than five days. This is made possible by a sophisticated software architecture and an efficient planning concept.

  • CyBio Composer
  • CyBio Scheduler
  • CyBio AppStudio

Comparison of air drying and active drying of samples

The active drying of the samples has a significant effect on the quality of the later analysis. The following comparison images illustrate how you can generate more homogeneous and thus higher quality spots with active drying of the MALDI-TOF-MS samples.

Air drying: DHBA in 50%acetonitrile +0.1% TFA

Active vacuum drying:DHBAin 50% acetonitrile +0.1% TFA

Air drying: Sinapinic acid in75% acetonitrile+0.1% TFA

Active vacuum drying:Sinapinic acid in 75%acetonitrile + 0.1% TFA

Air drying: HCCA in 70%nethanol + 0.1% TFA

Active vacuum drying: HCCAin 70% methanol+0.1% TFA

MALDI Sample Preparation Technology

Configuration examples MALDI sample preparation

Systems for automating MALDI sample preparation

Web Seminars

Web-Seminar MALDI-TOF Sample Prep - Scale up to 1 Mio. Samples a Week

Request advice

主站蜘蛛池模板: 桐乡市| 怀柔区| 九龙坡区| 罗甸县| 南昌县| 晋宁县| 孟州市| 丰城市| 布尔津县| 景宁| 孝感市| 河津市| 临潭县| 兴国县| 拜城县| 湘乡市| 犍为县| 阜新| 观塘区| 新宾| 乌拉特后旗| 兴宁市| 岑巩县| 黑水县| 岱山县| 九江县| 河西区| 浦县| 定兴县| 改则县| 勃利县| 沐川县| 巴南区| 秦皇岛市| 赫章县| 古浪县| 景东| 巴彦淖尔市| 会泽县| 百色市| 抚松县| 菏泽市| 金秀| 上林县| 海阳市| 苏尼特右旗| 灵武市| 玉门市| 内丘县| 四会市| 加查县| 海伦市| 成安县| 沅江市| 南召县| 蓝田县| 霍城县| 香港 | 西盟| 昆明市| 揭西县| 大安市| 吴旗县| 凯里市| 承德县| 米脂县| 全椒县| 镇原县| 城步| 平遥县| 格尔木市| 睢宁县| 永平县| 红河县| 罗江县| 锡林浩特市| 衡阳市| 黎川县| 磴口县| 香格里拉县| 桃园市| 宣汉县|